Safety Equipment Inspection Criteria
See EH&S safety equipment criteria for laboratory inspections.
|
Finding Script |
Finding Description |
Risk Level |
Reference |
|---|---|---|---|
|
Was a properly maintained first-aid kit found in the lab? |
A first-aid kit was not found, or one was not reasonably maintained and stocked, according to minimal requirements. Labs are responsible for obtaining a first-aid kit and periodically restocking and removing expired items. The first-aid kit needs to be easily accessible and always available for use. All personnel must be aware of its location. EH&S provides first-aid kits and restocks them upon request. For larger operations (number of personnel, physical space, special hazards), additional first-aid kits should be available or additional quantities of supplies should be included in the first-aid kits. |
Low |
To order or restock a first-aid kit, see First-Aid Kits for Research Laboratories and submit an online restocking request form. A link to minimum items for the first-aid kit is also available. |
|
Is there a sink for handwashing and handwashing supplies located within the laboratory area? |
A sink for handwashing with supplies (soap and towels) must be available within the laboratory area including tissue culture rooms or other procedure rooms. Exposure to hazardous materials and/or pathogenic organisms can occur by hand-to-mouth transmission. Handwashing is required after working with potentially hazardous materials and before leaving the laboratory. Contact your department to assess space needs or addition of a sink to the area. |
Medium |
|
|
Is access to the safety shower/eye wash station clear and free of obstructions? |
In the event of an emergency, people need access to the safety shower/eye wash station within 10 seconds. The person needing to use the safety shower/eye wash station may have impaired vision and be disoriented. Any obstruction to the safety equipment, no matter how small or easily moved, must be permanently removed. Always keep the area around the safety shower/eye wash station clear. Minimal clearance for safety shower/eye wash stations are: 16 inches from the center to either side, and 48 inches from the wall to in front of the station to remain clear at all times. Sink-mounted eye wash stations need to be accessible, activatable, and free of clutter. Remove obstruction(s) immediately. |
High |
Eye Wash and Emergency Shower Guidelines: Maintain Clearance Around Safety Equipment |
|
Are all the safety shower/eye wash stations within the lab checked monthly and documented on the attached inspection tag? |
Safety shower/eye wash stations are required to be tested at least once within each calendar month. This test is documented by initialing and dating the inspection tag that is attached to the unit. EH&S has a team dedicated to conduct this monthly testing. Contact ehsea@ucsd.edu or call 858-534-3660 if any station within the lab was not tested, failed a test, is missing an inspection tag and/or there are any other problems with the unit. EH&S does not service all areas; some restricted-access locations are self-checked. |
Low |
Eye Wash and Emergency Shower Guidelines: Make Sure Equipment is in Good Operating Condition |
|
Is there a safety shower/eye wash station located within 10 seconds of travel of any area where hazardous materials are used? |
In the event of an emergency, people need access to the safety shower/eye wash station within 10 seconds. A safety shower/eye wash station must be available within 10 seconds of unobstructed travel from where hazardous materials are used. To correct this finding either move the hazardous material use area closer to an existing safety shower/eye wash station or contact your department to assess space needs for addition of a safety shower/eye wash station to the area. |
High |
Eye Wash and Emergency Shower Guidelines: Location and Accessibility |
|
Is there a hazardous material spill kit and, if applicable, specialty hazard spill equipment and supplies available to lab personnel? |
Labs are required to have a sufficient spill kit to address general/specialty hazards. Specialty hazards are identified in the lab's Hazard Control Plans (HCPs). Spill kits need to be readily accessible and their location(s) should be known by all laboratory personnel. The HCP will outline the appropriate spill procedures and additional equipment to address the specific hazards, such as biohazardous materials, hydrofluoric acid, mercury, etc. For example, HCPs associated with a Biohazard Use Authorization (BUA) have a Spill Response section that includes information regarding chemical disinfectants and contact times. |
Low |
For more information, see Lab HCPs, How to Handle Chemical Spills in Laboratories and Small-Scale Chemical Spill Kits. |
|
Do all lab personnel wear lab coat and protective eyewear appropriate for the material or physical hazard they are directly working with, or adjacent to? |
Fitted lab coats and appropriately rated protective eyewear are required to be worn by all personnel handling hazardous materials. In addition, laboratory personnel occupying the adjacent area, who have the potential to be exposed to chemical splashes or other hazards as determined by the Laboratory Hazard Assessment (LHAT), are required to wear laboratory coats and protective eyewear. Lab coats must be of appropriate sleeve length and worn properly to prevent skin contact with hazardous materials. Flame Resistant (FR-rated) laboratory coats must be worn when working with large amounts of flammable liquids in laboratories using open flames or other potential ignition sources; or as determined by the LHAT. |
Medium |
|
|
Do all lab personnel wear the additional PPE as required by LHAT for the material or physical hazard they are directly working with, or adjacent to? |
Protective gloves, appropriate for the material or process being used, must be worn while using any hazardous material, hot or cold liquids (including cryogenics), objects that pose a risk of thermal burns, items having physical hazards, or equipment that may cause hand injury. The Safety Data Sheet (SDS) for the material, and the manufacturer-specific glove selection guide, should be referenced to determine appropriate glove type. Some operations and procedures may warrant additional personal protective equipment (PPE), as indicated by the SDS, Laboratory Hazard Assessment (LHAT), facility policies and/or regulatory requirements. Additional hazard-specific PPE might include face shields, aprons, respiratory protection, hearing protection, etc. |
Medium |
|
|
If an employee requires respiratory protection as PPE, are they enrolled in the Respiratory Protection Program? |
All respirator use on campus must be reviewed and approved prior to beginning work which necessitates its use. Employees who require respirators as PPE must be enrolled in the campus Respiratory Protection Program. Discontinue use of respirators until individuals are approved by the UC San Diego Industrial Hygiene Program. |
Medium |
Complete the online Respirator Hazard Evaluation Form to see if respiratory protection is required. |
|
Is PPE used and stored appropriately? |
Laboratory staff were observed using or storing personal protective equipment improperly. PPE must be worn according to manufacturer's guidance and implemented during activities calling for their use. Never wash or reuse disposable gloves. Respirators, lab coats, protective eyewear, face shields, etc. must be stored in a way to prevent contamination or damage. Individually assigned and fitted PPE should be labeled with the name of the assigned person to prevent misuse. Additionally, if using respirators, ensure all filtering face piece respirators and cartridges are stored in Ziploc bags or inside drawers to prevent contamination. They must be replaced according to manufacturer recommended timeline. |
Low |
|
|
Do all laboratory personnel wear the minimum attire when in a lab/tech area? |
The following minimum attire requirements pertain to all laboratories/technical areas where use or storage of hazardous materials occurs or a physical hazard exists: |
Medium |
Questions? Contact the EH&S Research Assistance Program.