Hazardous Waste Inspection Criteria
See EH&S hazardous waste criteria for laboratory inspections.
|
Finding Script |
Finding Description |
Risk Level |
Reference |
|---|---|---|---|
|
Are biohazardous sharps used appropriately? |
Biohazardous sharps were bent or recapped, or did not have engineered sharps protection devices. Sharps must never be bent, recapped, or modified otherwise. Sharps containers containing unapproved bent or recapped sharps should be closed and disposed of immediately in the lab's designated biohazard waste accumulation site. Use of sharps with human or non-human primate materials or BSL-2+ agents requires engineered protection devices, if available. Examples of engineered sharps protection devices include scalpel with a retractable blade, needle with syringe that retracts needle once content is dispensed, or blunt needles. For procedures requiring bending or recapping, or scientific reason for not using engineered sharps, a justification request must be submitted to the Institutional Biosafety Committee (IBC) for review and approval by amending the Biohazard Use Authorization (BUA) associated with the project. |
High |
|
|
Are vacuum flasks used for biological materials labeled appropriately? |
Vacuum flasks containing biohazardous materials were not labeled correctly. Vacuum flasks containing biological materials must be labeled with the contents and include the disinfectant used, if applicable. An example of an appropriate label is, "Tissue culture media disinfected with bleach". Ask the lab's Research Assistance Program (RAP) Specialist for these labels. |
Medium |
See Biosafety: How to Disinfect Tissue Culture Media in Vacuum Flasks for details and label templates. |
|
Are vacuum flasks containing biological materials used appropriately? |
A vacuum flask was contaminated, was not placed in a secondary container when stored on the floor, or was attached to a vacuum line that was left on. Vacuum flasks used to aspirate biohazardous liquids should contain bleach or other disinfectant, and they should be emptied and cleaned weekly, or when two-thirds full, to prevent overflow. Vacuum lines must be turned off when not in use. |
Medium |
See Biosafety: How to Disinfect Tissue Culture Media in Vacuum Flasks for details on proper usage of vacuum flasks. |
|
Are vacuum lines used for biological materials protected with a hydrophobic HEPA filters, and are filters replaced regularly or when deficient? |
Vacuum lines used for biological materials must be protected with an inline hydrophobic HEPA filter which must be placed between the flask and vacuum system. Filters must be replaced as needed—at a minimum, annually and when there is any evidence of deficiencies (e.g. filter blockage, failure, wetness). When changing out filters, dispose of them as red biohazardous waste bag, hazardous chemical waste, or radiological waste, as appropriate. |
Medium |
See Biosafety: How to Disinfect Tissue Culture Media in Vacuum Flasks for details on proper usage of vacuum flasks. |
|
Do autoclaves used for biohazardous waste have complete documentation? |
Autoclave used for biohazardous waste sterilization and decontamination had incomplete documentation. When an autoclave is used for biohazardous waste or CDC/USDA/APHIS/CDFA permit requirements, permit is posted on the autoclave, and a log of autoclave use must be maintained. This documentation must contain: use log, spore tests records, maintenance records and annual calibration records. |
Medium |
Review Autoclave: Biohazardous Waste for downloadable log template and more information. |
|
Are biohazard waste containers and/or biohazard sharps containers filled only to acceptable levels? |
Ensure containers can be closed, secured, and sealed for transport and disposal. When the container is three quarters full, close and tie off the interior bag, then close and tie off the exterior bag. Sharps should not extend above the FILL line of the sharps containers. Dispose of waste and disinfect secondary containers and other surfaces that may have been contaminated due to overfilling. |
Medium |
|
|
Are biohazardous sharps containers appropriate and properly labeled? |
Biohazard sharps containers must be FDA approved, rigid, puncture and leak resistant, and equipped with tight fitting cover. Containers must be labeled with the international biohazard symbol, the word "Biohazard," and specific generator information as follows: UC San Diego, Street address, City, State, Zip, Building, Room, and 858-534-HELP. |
Medium |
Biohazardous Containers and Bags Address templates are available for download on How to Manage Sharps. |
|
Are biohazardous sharps disposed of appropriately? |
Biohazardous sharps were placed in regular trash or non-sharps container. Biohazardous sharps container must be FDA approved, rigid, puncture and leak resistant, and equipped with tight fitting cover. Containers must be available wherever sharps may be used. Trash or waste containers found with improper disposal of sharps must be removed from use and trash/waste bag should be carefully placed within a sharps container for immediate disposal. Prior to resuming work, retrain lab personnel to properly dispose of sharps. Contact ehsrap@ucsd.edu if additional assistance is needed in appropriately disposing of sharps. |
High |
See examples of biohazardous sharps containers on How to Manage Sharps: Biohazardous Contaminated. |
|
Are all chemical waste containers that are not in active use closed/capped? |
Uncovered chemical waste containers that are not actively in use, or in a specific process, are in violation of chemical waste storage and disposal regulations. The EPA requires chemical waste containers to be closed when not in use. The purpose is also to prevent the perception of disposal via intentional evaporation, and reduce the likelihood of accidental spills. Note that containers that are defaced, labeled 'Empty' and are "California Empty" (e.g., there is no pourable liquid or powder when the container is held in any orientation) do not need to be closed/capped. |
Medium |
Review Hazardous Waste and Empty Research Container Management for more information. |
|
Are all chemical containers that are not in active use closed/capped? |
Uncovered chemical containers that are not actively in use, or in a specific process, are in violation of chemical storage regulations. Chemical containers are required to be closed when not in use to prevent evaporation and reduce the likelihood of accidental spills. Note that containers that are defaced, labeled 'Empty' and are "California Empty" (e.g., there is no pourable liquid or powder when the container is held in any orientation) do not need to be closed/capped. |
Medium |
Review Chemical Storage and Inventory and Empty Research Container Management for more information. |
|
Are all hazardous wastes disposed of according to EH&S Policy? |
Hazardous waste must be disposed of in such a way as to protect people, waterways, sewers, landfills and the environment. Only methods of disposal that have been vetted and approved by EH&S may be used. EH&S needs to be directly involved prior to any time hazardous waste is shipped from a UC San Diego location, including shipping manifests and documentation according to PPM 516-14. Notify hazwaste@ucsd.edu in advance of any shipments of hazardous waste. |
High |
|
|
Do all chemical waste containers have an appropriate OTP or accumulation waste tag attached and is within the allowed laboratory collection time limit? |
Chemical wastes are required to be labeled with an OTP or accumulation hazardous waste tag as soon as waste is put in the container. Tagged, hazardous waste containers cannot be stored for more than 90 days in the lab regardless of how full the container may be. Containers that exceed regulatory accumulation time limits can result in serious fines to the University. To generate an OTP tag and/or to schedule the pickup of laboratory hazardous waste use the My Research Safety web portal and select the "Online Waste Tag Program (OTP)" link. Note that hand-written waste tags are no longer acceptable. |
Medium |
Refer to How to Use UC San Diego Hazardous Waste Tags and Waste Tag Video Tutorials for more information. |
|
Are all chemical wastes stored using an appropriate container, cap, and secondary containment? |
All chemical waste must be in compatible containers with caps, kept closed when not actively adding waste, and not be overfilled beyond 90% of the container volume. Liquid waste primary container must be in adequate secondary containment and have a leak-proof, screw top cap. Utilize secondary containment to prevent leaks or spills from accidentally entering the sewer. Never use lab sinks as secondary containment for chemical storage. Waste containers must have an OTP tag attached and the original product label must be crossed out. Liquid and solid wastes must be accumulated separately. |
Medium |
See How to Store and Dispose of Hazardous Chemical Waste for more information. |
|
Are all non-biohazardous sharps in a rigid puncture proof container, within container fill-limits, labeled appropriately and within approved accumulation time period? |
All non-biohazardous sharps (including razor blades, box cutters, knives, scissors, glass pipettes, glass slides, etc.) need to be collected in an adequate rigid and puncture proof container. Sharps containers may never be filled beyond their fill-limits, meaning that the container must be easily closed without the manual shifting or redistribution of the contents. Sharps containers must be labeled clearly: for chemically contaminated and non-hazardous sharps an OTP tag is required and accumulation time limits apply (90 days for chemical contaminated and 240 days for non-contaminated/non-hazardous). To generate an OTP tag and/or to schedule a pickup of a tagged sharps container, use the My Research Safety web portal and select the "Online Waste Tag Program (OTP)" link. |
High |
Refer to How to Dispose of Sharps and How to Use UC San Diego Hazardous Waste Tags for more information. |
|
Are non-hazardous wastes managed properly? |
Nonhazardous waste was unlabeled or labeled improperly, or accumulated longer than 240 days. Waste was found to be mixed such that it interferes with the proper disposal/recycling of that waste. Box or container was compromised such that the container no longer can safely hold the waste for transport. |
Low |
See Empty Research Container Management and the Research Waste Disposal Guidelines poster for what can and cannot be disposed in this manner. |
|
Has a waste determination been conducted for all items being disposed down the drain/sink? |
A hazardous waste determination is needed for all items being disposed of down the sink. This process will ensure proper disposal of these items. For questions on this process, contact ehsrap@ucsd.edu.
|
Medium |
Review Sewer Disposal: What Can Go Down the Drain? along with instructions on How to Identify Hazardous Chemical Waste for help with classifying unidentifiable materials. Click on the hyperlink "Waste Determination Form" and follow the instructions for classification assistance. |
|
Are sharps containers used appropriately? |
Only sharps including needles with syringes and blood vials should be disposed of in a sharps container. Sharps containers must be assembled per manufacturer instructions and have the manufacturer lid in place prior to start of use. Solid/liquid hazardous waste, empty bottles, or regular trash, cannot be disposed in a sharps container. To rectify this, close the container lid, make an OTP tag for it if applicable, dispose through appropriate waste stream, and start a new sharps container. For questions on this process, contact ehsrap@ucsd.edu. |
Medium |
Review How to Manage Sharps and train the lab on how to dispose of lab items so that this doesn’t reoccur. |
|
Is scrap metal being disposed of appropriately? |
Scrap metal must be managed appropriately with the correct OTP tag. |
Medium |
See the Managing Scrap Metal Recycling and Disposal Flowchart (PDF) on Scrap Metal Recycling to determine if scrap metal is recyclable or hazardous waste. |
|
Are the EH&S Research Waste Disposal guidelines being followed? |
Research waste disposal guidelines were not followed or waste was not properly segregated. |
Medium |
Review the Research Waste Disposal Guidelines (PDF) and segregate waste appropriately. |
|
Has the lab made waste determinations for all unlabeled/waste-like materials? |
Individuals generating hazardous waste are required to classify unlabeled and waste-like materials via a hazardous waste determination. This process will ensure proper disposal of these items. For questions on this process, contact ehsrap@ucsd.edu. |
Medium |
For instructions on conducting a hazardous waste determination, review the Hazardous Waste Determination flowchart along with instructions on How to Identify Hazardous Chemical Waste. Click on the hyperlink "Waste Determination Form" and follow the instructions for classification assistance. |
|
Is all Universal Waste labeled appropriately, stored within allowable time limits and maintained properly? |
Universal waste is required to be stored and maintained to protect landfills, sewers, and the environment from contamination. Common types of universal waste generated by the university are used batteries, fluorescent light bulbs, etc. Federal regulations require all containers of universal waste generated by the university to be labeled appropriately, disposed of within 240 days of generation and collected within containers that will prevent an accidental spill or release. Label all universal waste containers with an OTP tag. To generate an OTP tag and/or to schedule the pickup of universal waste use the My Research Safety web portal and select the "Online Waste Tag Program (OTP)" link. |
Medium |
Refer to Universal and Electronic Waste Disposal and How to Use UC San Diego Hazardous Waste Tags for more information. |
|
Is all unwanted electronic equipment transferred appropriately? |
Unwanted electronic materials must be managed to protect people, waterways, sewers, landfills and the environment. Only methods of removal that have been vetted and approved by EH&S may be used. Prior to removal all electronic equipment used for/in a laboratory process must be decontaminated and documented. |
Medium |
Refer to Decontamination Clearance for Equipment or Facilities for disposal options and requirements. |
Questions? Contact the EH&S Research Assistance Program.