UC San Diego
Faculty and Staff
Site Search
Blink Logo
A-Z Sites Department Index
  • Blink Tabs
    • Buy & Pay
    • Facilities & Services
    • Faculty Resources
    • Finance
    • Human Resources
    • Research
    • Safety
    • Student / Class Info
    • Technology
    • Travel
  • Personal Tools
    • At Your Service via AYSO
    • At Your Service via SSO
    • Compensation Calculator
    • Enrollment Central
    • Job Bulletin
    • My Directory
    • My LeaveBalances
    • My Time
    • My Training
    • My Travel
    • SkillSoft eLearning
    • All tools
  • Business Tools
    • APOL
    • Connexxus
    • Marketplace
    • Title & Pay Look-up
    • MyApprovals
    • MyDashboard
    • MyEvents
    • MyFunds
    • MyTravel
    • EmployeeLink
    • FinancialLink
    • TravelLink
    • All tools
  • Instruction Tools
    • ASSIST
    • Class Lists
    • Degree Audit (DARs)
    • Find a Student
    • Majors List
    • Minors List
    • Schedule of Classes
    • Enrollment and Waitlists
    • WebCT
    • All tools
  • Research Tools
    • Proposal Repository
    • Faculty Expertise
    • Forms lister
    • Get Proposal #
    • Shared Facilities
    • FinancialLink
    • TravelLink
    • MyEffort
    • MyFunds
    • My Research Safety
    • MyTravel
    • All tools
  • Blink Home 
  • Safety 
  • Campus Emergencies & Security 
  • Emergency Preparedness 
  • Reducing Workplace Earthquake Hazards

Reducing Workplace Earthquake Hazards

Last updated August 25, 2009 12:57:42 PM PDT
Give more feedback

Reduce injuries and damage during earthquakes by securing nonstructural hazards, such as equipment, furniture, shelved items, and other building contents.

Securing nonstructural hazards improves safety by:

  • Reducing injuries and damage caused by falling and moving items
  • Maintaining clear exit paths from the building and access into the building for responders
  • Reducing the potential for hazardous material spills, fires, and utility leaks

Click on a topic for more information:

Expand all

Identify hazards

  • Identify unsecured objects that might fall, overturn, slide, spill, or rupture during shaking. Examples include:
    • Tall furniture and equipment
    • Equipment and furniture on wheels
    • Objects, equipment, containers, and materials in cabinets and on open shelves
    • Wall- or ceiling-mounted displays, art, pictures, and mirrors
    • Fixtures and utility conduits
    • Compressed gas cylinders
    • Other building contents
  • Secure items using methods described on this page. Devise other effective methods as needed.
    • Contact Continuity Emergency & Services, (858) 534-3823, if you need assistance.

Tall furniture and equipment

Department heads and PIs are responsible for ensuring that when equipment or furniture is moved or new equipment is delivered, it is secured to minimize movement during earthquakes.

Free-standing items or equipment over 42 inches in height and having a height which is 3 or more times greater than the smallest dimension of the base must be adequately secured in all UCSD facilities.

  • Bolt securely to the wall studs or move tall cabinets, bookcases, shelving, stacked items, or equipment so they will not overturn on people or block corridors or doorways if they fall or move.
  • Select a restraint material and method suitable for your purpose. Many commercially available tethers, cables, and angle brackets are available to secure heavy equipment and furniture to walls.
    • Consider:
      • Strength and flexibility of the restraint
      • How to anchor the restraint to a secure surface
      • Quick-release mechanisms if equipment must be moved for use
  • View images of different types of equipment restraints:
    • Biosafety cabinet anchored to the floor with a metal bracket
    • Equipment on casters
    • Wall-anchoring system with flexible tethers
    • Freezer tethered to wall-anchoring system
  • See illustrated methods for securing furniture and equipment:
    • Brackets at top or side
    • Free-standing shelving
    • File cabinets
  • Choose wide-based storage (deeper shelves) when possible. It's more stable. The taller and narrower furniture or equipment is, the more likely it is to tumble over.

Open shelves

Shelving in UCSD facilities containing chemicals, glassware, or hazardous equipment or materials must be provided with seismic restraints to resist shelf content movement, breakage, and reaction of chemicals.

  • Store heavy and breakable items on lower shelves. Less damage will be done if they fall.
    • Picture the item falling off during a tremor when placing something on an upper shelf. That image may help you decide where to store heavy items.
  • Use shelf lips to prevent light-weight containers and objects from vibrating off shelves. Shelf lip height requirements:
    • For shelving containing chemicals, glassware, or hazardous materials: Shelf lips must be at least 2 inches high from the shelf surface.
    • For low hazard areas such as offices, especially over employee work stations, shelf lips must be at least 1.5 inches high from the shelf surface.
  • Use eyehooks and loop material (fishing line, cord, thin wire, etc.) to restrain larger, heavier objects on shelves.
    • Note: Bungie cords are not as effective as other materials. Small items may slip under them.
  • Use adhesive products to secure light-weight objects on open shelves. Various commercial "putty-like" products are available. Adhesive-backed velcro is another option.
  • See illustrations of open shelf restraint methods:
    • Methods to secure items on open shelves
    • Bookcases

Cabinets

  • Use positive latching devices on cabinet doors.
    • Examples include slide bolts, safety hasps, and "child-proof" baby latches. Many types are readily available at hardware suppliers.
    • See illustrated types of cabinet latches.
  • Store heavy items on lower shelves. This prevents the cabinet from being top-heavy, and less damage will be done if they do fall.

Hanging items

  • Use closed hooks to hang mirrors, pictures, and other suspended objects so they can't jump off of during shaking.
  • Install strong brackets on the top, bottom, and sides of heavy mirrors and pictures — the preferred solution for heavy items.
    • Make sure the clips are anchored into the wall studs.
    • See illustrated methods for hanging pictures and mirrors.
  • Place only soft art or displays, such as unframed posters, rugs, and tapestries adjacent to areas where people sit or stand.

Computer equipment

Computer equipment crashing onto the floor has been a major business expense in earthquakes.

  • Secure desktop computers, monitors, and printers.
    • Choose from many commercially available products including velcro fasteners and non-slip pads.
    • Attach raised shelf edges to prevent low-profile equipment from vibrating off the edge.
    • See illustrated methods for securing desktop computer equipment.
  • Prepare server rooms.
    • Anchor stacking racks to protect personnel from falling equipment.
    • Consider restraint systems that allow some server movement to protect the unit from absorbing all the shock.
      • Examples of restraints for servers include the use of caster pads, caster wheel locks, sliding pads, elastomer bumpers, and tethers.
    • Consult the service provider for your equipment to determine the best method for securing your server environment.
  • Read Standards for Computer Server Rooms at UCSD for more information about institutional recommendations.

Compressed gas cylinders

Following the 1994 Northridge quake (magnitude 6.9), UC Los Angeles responders reported that several doorways were blocked by fallen cylinders, especially by cylinders stored behind doors. At the CSU-Northridge campus (closer to the epicenter of the quake), 3 out of their 4 science buildings suffered major fires during which over 50 cylinders exploded.

  • Secure cylinders in an upright position to a substantial, fixed surface with upper and lower restraints made of non-combustible material, preferably chain and Unistrut®.
    • View an image of properly secured cylinders.
    • Note: Single restraints are not as successful as upper and lower restraints. C-clamps are not reliable.

Special precautions for laboratories.

  • Plan for seismic restraints when designing your laboratory layout. Some equipment arrives ready for bracing.
    • View images of equipment restraints used in UCSD research facilities.
  • Segregate incompatible chemicals and hazardous materials and reactives.
    • Read Chemical Compatibility Guidelines.
  • Protect temperature-sensitive materials with a backup generator in case power is interrupted.
  • Read about securing compressed gas cylinders above.

Water heaters

  • Strap water heaters to a secure wall. Follow instructions for wall or corner locations:
    • Basic instructions
    • Wall
    • Corner

Fire doors and walls

Fire is possibile following an earthquake that has ruptured gas and water lines, broken electrical lines, or caused volatile hazardous materials to spill and react.

Fire walls and doors are specially constructed to withstand fire for a specified period of time, giving building occupants a chance to escape, and limiting damage.

  • Keep fire doors closed in your building to protect your exit corridors and stairs from smoke and fire.
  • Do not cut openings into fire-rated walls.
    • During the 1994 Northridge quake (magnitude 6.9), CSU Northridge responders reported that rooms next door to areas that were completely consumed by flames did not burn where fire doors were shut and fire walls had not been compromised.
    • An example of a “compromised fire wall” was seen where a display case had been installed in a wall extending through to the hall on the other side. Flames easily consumed the display case and escaped out into the hall through the hole in the fire wall where the display case had been.
  • Contact EH&S Fire & Life Safety, (858) 822-5706 or 534-3660, if you have questions about fire doors and walls.

Expand all

For more information, contact Continuity & Emergency Services, (858) 534-3823.

Safety

Emergency Preparedness

  • Automated External Defibrillator Locations
  • CERT (Campus Emergency Response Team)
  • Community Resources
  • Department Emergency Action Plans
  • Emergency Guide
  • Emergency Operations Plan
  • Emergency Supplies: Personal Checklist
  • Evacuation Procedures
  • Evacuation for People With Disabilities
  • Hazardous Materials Emergency Response Team
  • Medical Training Resources
  • Reducing Workplace Earthquake Hazards
  • Resources
  • Tsunamis and Southern California

Departments


Environment, Health & Safety

Continuity and Emergency Services

See Also


UCOP Seismic Safety Policy

PPM 516-12.2 Non-structural Seismic Hazard Reduction

UC San Diego 9500 Gilman Dr. La Jolla, CA 92093 (858) 534-2230
Copyright ©2009 Regents of the University of California. All rights reserved.
  • Terms & Conditions
  • Feedback
  • About Us
  • Accessibility
  • Emergency Info