Blink Home > Safety > Engineering Controls for Laboratory Safety
Make Blink yours!
 · Activate personalization
 · Learn about MyBlink
Get what you wanted?
yes no Comments

EmployeeLink This system is working normally. If you experience any
      problems, please report them to the ACT Help Desk at (858)534-1853
FinancialLink This system is working normally. If you experience any
      problems, please report them to the ACT Help Desk at (858)534-1853
TritonLink This system is working normally. If you experience any
      problems, please report them to the ACT Help Desk at (858)534-1853
TravelLink This system is working normally. If you experience any
      problems, please report them to the ACT Help Desk at (858)534-1853
  |  More...

At Your Service Online
    Via Single Sign-On
    Via AYSO password
MyApprovals
MyBlink
MyDashboard
MyDirectory
MyEffort
MyFunds
MyLeaveBalances
MyTime
MyTraining
MyTravel    |   Info ...
News and events
UCSD News
This Week @ UCSD
UCSD Calendar of Events
Staff Ed classes
Find What's New
Find the most recent articles by topic.
UCSD News & Information
UCSD Events Calendar
Blink online glossaryOnline glossary
Stumped by a word on Blink? Look it up!
Blink e-mail reminders Reminder Service
Blink can remind you of important events.
Department Index
Engineering Controls for Laboratory Safety  
 
Summary: Learn about engineering controls used at UCSD to protect laboratory workers from physical or chemical hazards.


Engineering controls reduce or eliminate exposure to chemical or physical hazards through one of the following methods:

  • Elimination of a hazardous technique, process, or material
  • Substitution of a less hazardous technique, process, or material for a more hazardous one
  • Segregation of people from hazards
  • Enclosure of hazards
  • Ventilation of the workplace and the source of contaminants
  • Repair or replacement of faulty equipment or machinery

Engineering controls are usually the most effective way to protect all laboratory workers because they make changes at the source of the hazards and don't rely on the skill or vigilance of individuals. Engineering controls are often used along with administrative measures and personal protective equipment.

The following engineering controls are in use at UCSD:

Building ventilationBuilding ventilation provides UCSD laboratories with at least 10 air changes per hour (ACH) of fresh (outside) air. This airflow reduces employee exposure to airborne contaminants and removes excess heat. It also directs the airflow from areas of lower hazard to areas of higher hazard, which helps keep odors and hazardous gases, dusts, and vapors out of hallways and other public areas.
Local exhaust systems and fume hoodsA local exhaust system has a hood that captures contaminants at their source before they escape into the workroom environment. To be effective, the hood must be within 10–12 inches of the source (closer is better). Drafts, traffic, and heating sources can impair the effectiveness of a local exhaust system.
  • Chemical fume hoods contain hazardous dusts, gases, vapors, and fumes that are generated within them and remove them via the building's ventilation system. When used properly, these hoods are extremely effective at protecting lab workers and the work environment, although they should not be used with biohazardous materials.
  • Wash-down fume hoods, for use with perchloric acid, are fitted with sprinklers to prevent explosive perchlorate crystals from forming.
  • "Snorkels" or "elephant trunks" are exhaust systems intended for small areas or machines.
Biosafety cabinets (BSCs) Biosafety cabinets use HEPA filters to protect lab workers and the environment from aerosols or droplets that could spread biohazardous material.
Shielding for radiationRadiation shielding varies from lead bricks to plastic (Lucite) panels, depending on the type of radiation involved. Different thicknesses of these materials are used, depending on the energy of the radiation.
Shielding for blood and body fluid splatterThis physical barrier is especially useful for opening vacutainer tubes or other potential splatter activities.
Glove boxes Glove boxes are airtight boxes with 2 or more heavy rubber gloves and an airlock. Use them when working with known carcinogens and highly toxic substances, or to provide an inert atmosphere for compounds that are sensitive to water or air. Glove bags are an economic alternative for short-term uses.
Gas cabinetsUse gas cabinets to house hazardous gas cylinders, such as hydrogen or arsine. Cylinders containing nontoxic, oxidizing, or flammable gas used in fume hood applications do not require the use of a gas cabinet. In some cases, pyrophoric, corrosive, and toxic gases may be kept in a fume hood.
Clean benchesAlso called laminar flow benches, clean benches DO NOT protect people or the environment. Their only purpose is to provide a clean, HEPA-filtered work area. They do not recirculate or filter air. If you work with hazardous materials, use a fume hood or biosafety cabinet instead.

If you're a UCSD employee and have questions, contact an EH&S Research Assistance Program specialist.

  Print
Print
this page
  Email
Share
this page
  Add to MyBlink
Save
this link
  Get notified when this page is updated
Notify
on change
  Add a sticky note to this page
Add
a note
 


Last reviewed/updated on April 14, 2008 (see more info)
Blink A-Z Index:   0-9  A B C D E F G H  I  J K L M N O P Q R S T U V W X Y Z 


Blink Home  Site Map  Help  Accessibility Tips  Privacy Statement  Content Manager  RSS Feed 


Copyright ©2008 Regents of the University of California. All rights reserved.
Official Web Page of the University of California, San Diego

Blink version 1.7 12-17/2007 Blink Usability Group